SDSFE31xx-100 Industrial Device Server Transition Networks
24-Hour Technical Support: 1-800-260-1312 International: 00-1-952-941-7600
13
Connecting power to the Device Server, continued
CAUTION
When connecting DC power wires to the terminal-block plug, pay close
attention to the polarity markings shown near the terminal block of the Device
Server. Failure to observe this caution could result in damage to the device.
Terminal-block
plug wiring
To wire the six-contact-terminal-block plug for redundant power, do the following:
Note: The six-contact-terminal-block plug is constructed (keyed) to mate with the
Device Server terminal block. When wiring the plug for power, use the
polarity markings next to the terminal block on top of the Device Server to
ensure proper connection.
Step Action
1. Turn the external power source OFF.
2. Strip the power wires as required.
3. Insert one stripped power wire into the terminal-block plug, Observe
polarity. See Figure 7.
4. Secure the wire using a flathead screwdriver by tightening the contact
screw. See Figure 7.
5. Repeat Steps 3 and 4 until all wires are installed and secured.
Figure 7: Six-Contact-Terminal-Block Plug (Primary/Redundant Power Wiring)
Continued on next page